Maintenance Technology August 2016 - (Page 26)

MAINTENANCE STRATEGIES Rethink Overall Vibration Monitoring OVERALL VALUES ARE the most common measurements and calculations used in vibration analysis. What's more, some reliability and maintenance programs rely solely on them. The goal is to remove monitored equipment from service once the overall vibration level exceeds a certain threshold. Although this approach would appear to be quite cost effective, in reality it frequently isn't. In fact, overall vibration monitoring can become extremely costly for a facility. The dilemma High vibration levels can be caused by internal and external sources. They include, among others, imbalance, misalignment, belt defects, mechanical looseness, bearing-related issues, gear defects, and cavitation. Once identified, they should all be corrected. Keep in mind, however, that equipment often experiences multiple defects at once. For example, it's possible for the amplitudes of certain frequencies to increase while the amplitudes of other frequencies decrease. The fact that these situations indicate a variety of specific conditions poses a problem for those relying solely on the overall-vibration approach. An overall vibration value is centered on the frequency range being acquired and calculated based on a formula selected by the manufacturer of the vibration-monitoring device. Expressed in a mathematical representation of the energy exhibited by all defects combined, plus the vibration currently experienced in the machine, the overall vibration value cannot accurately differentiate among defects caused by various machine conditions. The solutions What should you do once an overall vibration level exceeds your target amplitude and the equipment is removed from service? First, stop with the assumptions. They're often made about the causes of high overall values, and work is completed based on them. Relying solely on overall values and only making assumptions about their cause can easily lead to incomplete information about the health of your equipment. This, in turn, can lead to misguided equipment repairs or detection of problems only in the painfully late stages of failure. As a result, extra resources and efforts are invested in determining the true 26 | MAINTENANCE TECHNOLOGY Clinging to a single approach that made economic sense for your plant 'back in the day' could be an expensive strategy. Trent Phillips, CMRP, CRL Novelis source of elevated vibration levels-which translates as misspent time, unnecessary equipment maintenance, increased costs, and unwanted downtime. There are several actions you can take to ensure your vibration program is effective, i.e., that it correctly identifies conditional changes in the equipment and sources of vibration. ■ Make sure the most important equipment in the facility is monitored. Don't arbitrarily assign monitoring intervals. ■ Confirm that monitoring intervals allow enough time to identify, plan, schedule, and correct the identified findings before unwanted equipment failures occur. ■ Verify that recommendations are implemented. Knowingly ignoring conditional changes in equipment health will result in downtime, extra cost, and lower capacity. Be sure you understand the failure modes in each machine, based on principles of FMEA (failure-mode-effects analysis). Band alarms and analysis should be used to indicate changes in the condition of your equipment and, at the same time, identify their causes or sources. Specific bands can be easily created, measured, and trended around particular failure modes in equipment, including misalignment, imbalance, and bearings. This information leads to more accurate alerts of impending failure conditions than generic overall measurements-and, as an extra benefit, actually identifies the failing component. Personnel considerations Who should collect routine vibration data? This is an important issue given the fact that wasted time wastes dollars. Operators and mechanics should be up to the task. Both can acquire comprehensive vibration measurements on equipment during the course of their normal work activities. They also can make sure machines are shut down if vibration levels exceed acceptable values and notify others regarding the need for corrective actions. This approach allows analysts to focus on collected data and determining root causes of defects. Data considerations What other valuable condition-monitoring data might be missing? Tracking process information such as temperatures, AUGUST 2016

Table of Contents for the Digital Edition of Maintenance Technology August 2016

Editorial
Uptime
On The Floor
Accepting The Challenge
Advanced Software In The Jungle
Put Efficiency in MRO Storerooms
Rethink Overall Vibration Monitoring
Reliable Pumping Supplement
Practical Oil Analysis: Why and What For?
SAP Tips and Tricks
Maximize Ethernet
Compressed Air Care
Nurture STEM Learning
Heed Drive-Belt Temps
Internet of Things
ISO 55000
Products
Showcase
Ad Index
Final Thought

Maintenance Technology August 2016

https://www.nxtbook.com/atp/MaintenanceTechnology/efficient-plant-jan-feb-2024
https://www.nxtbook.com/atp/MaintenanceTechnology/efficient-plant-april-2022
https://www.nxtbook.com/atp/MaintenanceTechnology/efficient-plant-october-2021
https://www.nxtbook.com/atp/MaintenanceTechnology/efficient-plant-june-2021
https://www.nxtbook.com/atp/MaintenanceTechnology/epapril2021
https://www.nxtbook.com/atp/MaintenanceTechnology/epmarch2021
https://www.nxtbook.com/atp/MaintenanceTechnology/epjanfeb2021
https://www.nxtbook.com/atp/MaintenanceTechnology/epjulyaug2020
https://www.nxtbook.com/atp/MaintenanceTechnology/epjune2020
https://www.nxtbook.com/atp/MaintenanceTechnology/epmay2020
https://www.nxtbook.com/atp/MaintenanceTechnology/epapril2020
https://www.nxtbook.com/atp/MaintenanceTechnology/epmarch2020
https://www.nxtbook.com/atp/MaintenanceTechnology/epfeb2020
https://www.nxtbook.com/atp/MaintenanceTechnology/epjan2019
https://www.nxtbook.com/atp/MaintenanceTechnology/epnovdec2019
https://www.nxtbook.com/atp/MaintenanceTechnology/epseptoct2019
https://www.nxtbook.com/atp/MaintenanceTechnology/epmay2019
https://www.nxtbook.com/atp/MaintenanceTechnology/epapril2019
https://www.nxtbook.com/atp/MaintenanceTechnology/epmarch2019
https://www.nxtbook.com/atp/MaintenanceTechnology/epfebruary2019
https://www.nxtbook.com/atp/MaintenanceTechnology/epjanuary2019
https://www.nxtbook.com/atp/MaintenanceTechnology/epdecember2018
https://www.nxtbook.com/atp/MaintenanceTechnology/epnovember2018
https://www.nxtbook.com/atp/MaintenanceTechnology/epoctober2018
https://www.nxtbook.com/atp/MaintenanceTechnology/epseptember2019
https://www.nxtbook.com/atp/MaintenanceTechnology/epaugust2018
https://www.nxtbook.com/atp/MaintenanceTechnology/0818schneider
https://www.nxtbook.com/atp/MaintenanceTechnology/epjuly2018
https://www.nxtbook.com/atp/MaintenanceTechnology/epjune2018
https://www.nxtbook.com/atp/MaintenanceTechnology/epmay2018
https://www.nxtbook.com/atp/MaintenanceTechnology/epapril2018
https://www.nxtbook.com/atp/MaintenanceTechnology/epmarch2018
https://www.nxtbook.com/atp/MaintenanceTechnology/epfebruary2018
https://www.nxtbook.com/atp/MaintenanceTechnology/epjanuary2018
https://www.nxtbook.com/atp/MaintenanceTechnology/epdecember2017
https://www.nxtbook.com/atp/MaintenanceTechnology/epnovember2017
https://www.nxtbook.com/atp/MaintenanceTechnology/epoctober2017
https://www.nxtbook.com/atp/MaintenanceTechnology/mtsept2017
https://www.nxtbook.com/atp/MaintenanceTechnology/mtaugust2017
https://www.nxtbook.com/atp/MaintenanceTechnology/mtjuly2017
https://www.nxtbook.com/atp/MaintenanceTechnology/mtjune2017
https://www.nxtbook.com/atp/MaintenanceTechnology/mtmay2017
https://www.nxtbook.com/atp/MaintenanceTechnology/mtapril2017
https://www.nxtbook.com/atp/MaintenanceTechnology/mtmarch2017
https://www.nxtbook.com/atp/MaintenanceTechnology/mtfebruary2017
https://www.nxtbook.com/atp/MaintenanceTechnology/mtjanuary2017
https://www.nxtbook.com/atp/MaintenanceTechnology/mtdecember2016
https://www.nxtbook.com/atp/MaintenanceTechnology/mtnovember2016
https://www.nxtbook.com/atp/MaintenanceTechnology/mtoctober2016
https://www.nxtbook.com/atp/MaintenanceTechnology/mtseptember2016
https://www.nxtbook.com/atp/MaintenanceTechnology/mtaugust2016
https://www.nxtbook.com/atp/MaintenanceTechnology/mtjuly2016
https://www.nxtbook.com/atp/MaintenanceTechnology/mtjune2016
https://www.nxtbook.com/atp/MaintenanceTechnology/mtmay2016
https://www.nxtbook.com/atp/MaintenanceTechnology/mtapril2016
https://www.nxtbook.com/atp/MaintenanceTechnology/mtmarch2016
https://www.nxtbook.com/atp/MaintenanceTechnology/mtfebruary2016
https://www.nxtbook.com/atp/MaintenanceTechnology/mtjanuary2016
https://www.nxtbook.com/atp/MaintenanceTechnology/mtdecember2015
https://www.nxtbook.com/atp/MaintenanceTechnology/mtnovember2015
https://www.nxtbook.com/atp/MaintenanceTechnology/mtoctober2015
https://www.nxtbook.com/atp/MaintenanceTechnology/mtseptember2015
https://www.nxtbook.com/atp/MaintenanceTechnology/MTAugust2015
https://www.nxtbook.com/atp/MaintenanceTechnology/MTJuly2015
https://www.nxtbook.com/atp/MaintenanceTechnology/MTJune2015
https://www.nxtbook.com/atp/MaintenanceTechnology/M
https://www.nxtbook.com/atp/MaintenanceTechnology/0415endress
https://www.nxtbook.com/atp/MaintenanceTechnology/MTApril2015
https://www.nxtbook.com/atp/MaintenanceTechnology/MTMarch2015
https://www.nxtbook.com/atp/MaintenanceTechnology/MTFebruary2015
https://www.nxtbook.com/atp/MaintenanceTechnology/MTJanuary2015
https://www.nxtbook.com/atp/MaintenanceTechnology/MTDecember2014
https://www.nxtbook.com/atp/MaintenanceTechnology/MTNovember2014
https://www.nxtbook.com/atp/MaintenanceTechnology/MTOctober2014
https://www.nxtbook.com/atp/MaintenanceTechnology/MTSeptember2014
https://www.nxtbook.com/atp/MaintenanceTechnology/MTAugust2014
https://www.nxtbook.com/atp/MaintenanceTechnology/MTJuly2014
https://www.nxtbookmedia.com