Overview | FAS Track HOW Products FAS® J -Track Shaft Wall ' 10 FAS® J-Track Provides the Same Great Benefits of FAS Track 1000 Within a Shaft Wall Assembly 0.50" * FAS J-Track has longer legs than standard J-Runner to provide greater deflection at the head-of-wall joint . INTUMESCENT TAPE * FAS J-Track provides ¾" overall unencumbered movement . 1.50" * FAS J-Track provides the best possible L-Rating (smoke) for 12.50" and 2 hour fire ratings . 33 MIL * FAS J-Track eliminates the installation of fire caulking or additional drywall rips . 0.50" 1.50" FAS J-Track is fabricated from hot-dipped galvanized steel complying with ASTM A653, and ASTM A1003 Grade 33 Type H for 33 ksi yield 2.50", 4".with 6" a minimum G40 coating strength steel for 33 mils (20 gauge) complying with ASTM A1003 . FAS J-Track has been tested with Underwritten Laboratories in accordance with UL 2079 for shaft wall assemblies . INTUMESCENT TAPE 2.50" 33 MIL 2.50", 4". 6" CEMCO FAS J-Track Allowable Loads and Heights Model No. Design Thickness (in.) Minimum Thickness (in.) Yield (KSI) Coating Web Sizes (in.) Gap (in.) Stud Spacing (in.) 12 33 mil 0.0346 0.0329 33 G40 2-1/2, 4, 6 3/4" 16 24 Lateral Load (PSF) 5 7.5 10 5 7.5 10 5 7.5 10 Max Load (LB) Max Height 75 22' 5" 15' 0" 11' 2" 22' 7" 15' 0" 11' 3" 19' 0" 12' 8" 9' 6" NOTE: BASED ON TEST RESULTS Head of Wall Systems | www.cemcosteel.com | 800.775.2362 13http://www.cemcosteel.com