Typical Details | FAS Strap HW-D-0524 1HR. OFFSET & PARALLEL UNDER FLUTED DECK FLUTED METAL DECK FILLED WITH CONCRETE CEMCO FAS STRAP HW-D-0524 2 HR. PARALLEL & DIRECTLY UNDER DECK FLUTE FLUTED METAL DECK FILLED WITH CONCRETE MIN. #6 FRAMING SCREW BY DESIGN CEMCO FAS STRAP TYPICAL STEEL FASTENERS BY DESIGN 1" NOMINAL GAP (2" JOINT PROTECTION) DRYWALL SCREW 1" LOWER THAN TRACK LEG CEMCO DEFLECTION DRIFT ANGLE - DDA (BOTH SIDES) #8 x 1/2" FRAMING SCREW CEMCO SLOTTED TRACK METAL STUD BY DESIGN 3/4" JOINT PROTECTION #8 x 1/2" FRAMING SCREW CEMCO FAS TRACK 1000 DRYWALL SCREW 1" LOWER THAN TRACK LEG METAL STUD BY DESIGN 5/8" TYPE "X" DRYWALL 5/8" TYPE "X" DRYWALL CONFIGURATION "A" *NOTE: SINGLE LAYER OF 5/8" TYPE "X" DRYWALL FOR 1 HOUR FIRE RATING, 2 LAYERS FOR 2 HOUR *NOTE: SINGLE LAYER OF 5/8" TYPE "X" DRYWALL FOR 1 HOUR FIRE RATING, 2 LAYERS FOR 2 HOUR HW-D-0524 1 HR. SHAFT WALL, PARALLEL & DIRECTLY UNDER DECK FLUTE HW-D-0524 2 HR. SHAFT WALL, PARALLEL & DIRECTLY UNDER DECK FLUTE FLUTED METAL DECK WITH CONCRETE FLUTED METAL DECK WITH CONCRETE CEMCO FAS STRAP CEMCO FAS STRAP 1" NOMINAL GAP (2" JOINT PROTECTION) CEMCO DEFLECTION DRIFT ANGLE - DDA (3 4" JOINT PROTECTION) CEMCO SLOTTED TRACK MINERAL WOOL 5/8" TYPE "X" DRYWALL CEMCO FAS J-TRACK MINERAL WOOL CH STUD 5/8" TYPE "X" DRYWALL 1" SHAFT LINER CH STUD 1" SHAFT LINER CONFIGURATION "A" *NOTE: SINGLE LAYER OF 5/8" TYPE "X" DRYWALL FOR 1 HOUR FIRE RATING, 2 LAYERS FOR 2 HOUR 34 *NOTE: SINGLE LAYER OF 5/8" TYPE "X" DRYWALL FOR 1 HOUR FIRE RATING, 2 LAYERS FOR 2 HOUR Head of Wall Systems | www.cemcosteel.com | 800.775.2362http://www.cemcosteel.com