Appliance Design - September 2008 - (Page 54) CONNECTORS & CORDS Annex O.2 to IEC 60335-1 provides an overview. (See Chart 1.) Unattended vs. attended There is a mandatory test procedure for carrying out glow wire tests. The temperature of the glow wire is calibrated and the test is carried out at intervals of 25 DegC. A product is therefore passed at 750 DegC if the material ignites only at 775 DegC. Therefore, for all unattended appliances with a current load on contact above 200 mA, Paragraph 30.2.3 requires that: Either the plastic material has a GWFI (Glow Wire Flammability Index) in accordance with IEC 60695-2-12 of 850 DegC, or The plastic material has a GWIT (Glow Wire Ignition Temperature) of 775 DegC in line with board testing according to IEC 606952-13, or The tested connector body does not ignite at a glow wire temperature of 750 DegC (and/ or burns < 2 seconds). If, however, the connector body does ignite at 750 DegC, all the parts surrounding the connector must either withstand a needle flame test, or comply with UL94 V-1, or better. For all unattended appliances with a 200 mA current load or less on contact (also paragraph 30.2.3), the following applies: Either the plastic material has a GWIT (Glow Wire Ignition Temperature) of 675 DegC in line with board testing according to IEC 60695-2-13, or The tested connector body does not ignite at a glow wire temperature of 650 DegC (and/ or burns < 2 seconds). If, however, the connector body does ignite at 650 DegC, all the parts surrounding the connector must either withstand a needle flame test or comply with UL94 V-1 or better. According to Paragraph 30.2.2, the following applies for attended appliances: At a current load above 500 mA, the connector body does not ignite at a glow wire temperature of 750 DegC. At a current load of 500 mA or less, the connector body does not ignite at a glow wire temperature of 650 DegC. In addition, according to Paragraph 3.2, all printed circuit boards in low-power appliances which are not handheld, such as tabletop or Chart 1. Annex O.2 to IEC 60335-1 provides an overview. floor-mounted appliances, must meet UL-94 V-0 and withstand the needle flame test. Supplier solutions Suppliers of plastic materials have developed new products that meet these requirements. The connector industry is demanding that these new plastics have the same attributes (in terms of processing and shrinkage factors) so that they can be processed in existing injection molds. If existing injection molds had to be retooled due to different processing parameters, those additional costs plus the higher costs of plastics would inevitably impact connector prices and thereby make end products more expensive. The plastics industry offers a range of GWIT products for PA-based materials, but for PBTbased products the choice is more limited. All of this would be tolerable if the test methods produced unambiguous results. For example, housing wall thicknesses play a crucial role in test strategies. One might wonder which direction and which surfaces are to be used for the glow wire test. On some plastics, gas emissions that ignite during the glow wire test can lead to different assessments, even at professional test centers. For these reasons, connector manufacturers and appliance manufacturers have upgraded their test laboratories to obtain a clear overview for themselves. The bottom line, however, is that only statements from an independent test laboratory count. Unfortunately this situation has not been ful- ly clarified fully by standards bodies. Everyone involved complains that a test interval of 25 DegC is too narrow. (In other words, if a material does not ignite at 750 DegC, but ignites at 775 DegC, it has withstood 750 DegC). Additionally, test equipment must cool down during the test procedure in order to obtain clear results. Molex is endeavoring to successively examine all connectors deployed in this area in accordance with IEC 695-2-1. For example, the Sabre (7.5 mm pitch), MLX (6.35 mm pitch), KK (5.08 and 3.96 mm pitch), SPOX (5.08, 3.96 and 2.5 mm pitch), RAST (5.0 and 2.5 mm pitch), Mini-Fit (4.2 mm pitch) and Micro-Fit (3.0 mm pitch) connectors will all be adapted to meet the requirements of IEC 60335-1 by using better plastics. In that case, there will be more new part numbers, new approvals, and new entries into customer parts lists, much to the chagrin of those affected, but at least going in the direction of consumer safety. Additional measures must be implemented for connectors with a non-compliant GWIT, such as metal coverings or firewalls, in order to ensure that the appliance does not ignite in the event of an overload. All parties are dutybound to exercise discipline and fairness to provide consumers — those who are ultimately affected — the plain truth. < For more information, email: amerinfo@molex.com 54 applianceDESIGN September 2008 www.applianceDESIGN.com http://www.appliancedesign.com
For optimal viewing of this digital publication, please enable JavaScript and then refresh the page. If you would like to try to load the digital publication without using Flash Player detection, please click here.