Engineered Systems - September 2008 - (Page 18) SHERLOCK REFRIGERANT LEAK MONITORING R-11 R-12 R-22 R-114 R-123 R-134A R-401A(MP39) R-401B(MP62) R-402A(HP80) R-404A(HP62) R-407C R-408A(FX10) R-409A(FX56) R-410A(Puron) R-500 R-502 R-507A(AZ50) R-717(NH3) Call the factory for list of additional refrigerants CaseInPoint Efficient HVAC and duct wrap team up at high-tech high school When officials in the School City of Hobart district in Hobart, IN, made plans to build a new, expansive, high-tech high school, one of the focal points was having energy-efficient mechanical systems. School City of Hobart hired Envoy, Inc., of Indianapolis, as construction manager and Gibraltar Design, Inc., an Indianapolis-based, full-service A/E and design firm, to design and build an efficient new school with high-tech features to prepare students for the world of tomorrow. Some of the school’s standout amenities include a 650-seat auditorium with a modern acoustics and sound system, a new football stadium, a 10,000 sq-ft media center with a coffee bar for students and a professional library for teachers, PCs or laptop computers in every classroom, wireless Internet, and several other technological features. Students will continue to attend the existing Hobart High School facility until the completion of the Fall 2008 semester. When it came to the HVAC system portion of the project, Gibraltar Design’s specifications included a VAV distribution system for the school’s classrooms with fan-powered boxes and terminal reheat. For the large gathering areas, Gibraltar’s design called for constant air volume distribution systems. The building’s cooling system is a water cooled centrifugal chiller, and the school will be heated with high-efficiency condensing boilers. The duct system consists of about 200,000 sq ft of galvanized steel ductwork. GE NE SI S Qu ali ty tha ts ESM09074Gen.indd 1 EVERYTHING FOR ASHRAE 15-2004 AND MECHANICAL CODE COMPLIANCE The SHERLOCK Refrigerant Gas Monitoring System is an extensive family of monitoring panels, sensors, external alarms, and breathing apparatus designed to make any machine room code compliant. The SHERLOCK line includes electronic monitors with either two or three alarm levels. Each alarm level has two relay outputs for various functions including activating audio-visual alarm indication devices, energizing exhaust fans or notifying the building automation system. The SHERLOCK sensor modules utilize both solid state CMOS for engine room and ventline which meet most specifications and budget considerations or infrared (IR) sensor technology, when accuracy is extremely important. The IR will virtually eliminate all false alarming. SHERLOCK also can provide several varieties of Self Contained Breathing Apparatus to meet the requirements of most mechanical safety codes. GENESIS INTERNATIONAL, INC. 1040 Fox Chase Industrial Drive Arnold, MO 63010 Phone: (636) 282-0011 Email:mail@genesis-international.com FAX: (636) 282-2722 Web:www.Genesis-International.com Input 136 at www.esmagazine.com/instantproductinfo When it has to be stainless, it has to be A-J! A-J Manufacturing offers a complete line of custom and standard stainless steel air distribution products, all designed and manufactured to offer durable, dependable and low maintenance performance necessary for food processing and manufacturing facilities. What’s more, with our state-of-the-art manufacturing capabilities, we can also offer you the industry’s shortest lead times for custom orders. So for continuous linear, security grilles, modular diffusers and much more, contact A-J Manufacturing today! A-J Manufacturing 800-247-5746 • www.ajmfg.com Input 13 at www.esmagazine.com/instantproductinfo tar ts i plus: TUCKING THE DUCT IN To provide added thermal efficiency to the ductwork, Gibraltar Design 8/14/07 11:30:24 AM specified duct wrap for the HVAC design. With the recommendation of Coleman Insulation Company, the project’s mechanical insulation contractor, Gibraltar Design selected CertainTeed® SoftTouch™ Duct Wrap, a resilient fiberglass blanket insulation applied to the exterior of sheet metal ductwork to seal potential leaks, preThe experts in stainless venting loss of valuable heated or cooled air. “We were looking for a good-quality, energy-efficient duct wrap that steel clean air systems could be installed at a lower cost,” said Craig Carlson, project engineer for for food processing, • Custom fabrication • Rush deliveries nt he be SHERLOCK CONTROLS SOLID STATE & GAS SPECIFIC INFRARED SENSOR ALARM INDICATION DEVICES gin SELF-CONTAINED BREATHING APPARATUS nin g! Seeking to make this new high school energy-efficient, designers specified a resilient fiberglass blanket insulation to blanket about 200,000 sq ft of galvanized steel ductwork. The wrap is designed to seal potential leaks and prevent loss of conditioned air. 18 En gi neer ed S y stem s September 2008 12/13/07 2:38:11 PM ES03084AJWasteFood.indd 1 http://www.esmagazine.com/instantproductinfo http://www.ajmfg.com http://www.esmagazine.com/instantproductinfo
Table of Contents Feed for the Digital Edition of Engineered Systems - September 2008 Engineered Systems - September 2008 Contents Editor's Note HVAC Challenge Back2Basics Case In Point Commissioning Building Automation HVACR Designer Tips Application Checklist LEED®, Or Get (It) Out Of The Way? BACnet Supplement Race To Market Steam Humidification In Pharmaceutical Facilities Outside Air, Inside Data Centers Forecast: Increasingly Cloudy And Under Control Products Computers & Software Literature Glossary Classifieds Advertiser Index Tomorrow's Environment Engineered Systems - September 2008 Engineered Systems - September 2008 - Engineered Systems - September 2008 (Page Cover1) Engineered Systems - September 2008 - Engineered Systems - September 2008 (Page Cover2) Engineered Systems - September 2008 - Engineered Systems - September 2008 (Page 3) Engineered Systems - September 2008 - Contents (Page 4) Engineered Systems - September 2008 - Contents (Page 5) Engineered Systems - September 2008 - Contents (Page 6) Engineered Systems - September 2008 - Contents (Page 7) Engineered Systems - September 2008 - Editor's Note (Page 8) Engineered Systems - September 2008 - Editor's Note (Page 9) Engineered Systems - September 2008 - HVAC Challenge (Page 10) Engineered Systems - September 2008 - HVAC Challenge (Page 11) Engineered Systems - September 2008 - Back2Basics (Page 12) Engineered Systems - September 2008 - Back2Basics (Page 13) Engineered Systems - September 2008 - Case In Point (Page 14) Engineered Systems - September 2008 - Case In Point (Page 15) Engineered Systems - September 2008 - Case In Point (Page 16) Engineered Systems - September 2008 - Case In Point (Page 17) Engineered Systems - September 2008 - Case In Point (Page 18) Engineered Systems - September 2008 - Case In Point (Page 19) Engineered Systems - September 2008 - Case In Point (Page 20) Engineered Systems - September 2008 - Case In Point (Page 21) Engineered Systems - September 2008 - Case In Point (Page 22) Engineered Systems - September 2008 - Case In Point (Page 23) Engineered Systems - September 2008 - Case In Point (Page 24) Engineered Systems - September 2008 - Case In Point (Page 25) Engineered Systems - September 2008 - Case In Point (Page 26) Engineered Systems - September 2008 - Case In Point (Page 27) Engineered Systems - September 2008 - Commissioning (Page 28) Engineered Systems - September 2008 - Commissioning (Page 29) Engineered Systems - September 2008 - Building Automation (Page 30) Engineered Systems - September 2008 - Building Automation (Page 31) Engineered Systems - September 2008 - HVACR Designer Tips (Page 32) Engineered Systems - September 2008 - HVACR Designer Tips (Page 33) Engineered Systems - September 2008 - Application Checklist (Page 34) Engineered Systems - September 2008 - Application Checklist (Page 35) Engineered Systems - September 2008 - LEED®, Or Get (It) Out Of The Way? (Page 36) Engineered Systems - September 2008 - LEED®, Or Get (It) Out Of The Way? (Page 37) Engineered Systems - September 2008 - LEED®, Or Get (It) Out Of The Way? (Page 38) Engineered Systems - September 2008 - LEED®, Or Get (It) Out Of The Way? (Page 39) Engineered Systems - September 2008 - LEED®, Or Get (It) Out Of The Way? (Page 40) Engineered Systems - September 2008 - LEED®, Or Get (It) Out Of The Way? (Page 41) Engineered Systems - September 2008 - LEED®, Or Get (It) Out Of The Way? (Page 42) Engineered Systems - September 2008 - LEED®, Or Get (It) Out Of The Way? (Page 43) Engineered Systems - September 2008 - LEED®, Or Get (It) Out Of The Way? (Page 44) Engineered Systems - September 2008 - BACnet Supplement (Page 1B) Engineered Systems - September 2008 - BACnet Supplement (Page 2B) Engineered Systems - September 2008 - BACnet Supplement (Page 3B) Engineered Systems - September 2008 - BACnet Supplement (Page 4B) Engineered Systems - September 2008 - BACnet Supplement (Page 5B) Engineered Systems - September 2008 - BACnet Supplement (Page 6B) Engineered Systems - September 2008 - BACnet Supplement (Page 7B) Engineered Systems - September 2008 - BACnet Supplement (Page 8B) Engineered Systems - September 2008 - BACnet Supplement (Page 9B) Engineered Systems - September 2008 - BACnet Supplement (Page 10B) Engineered Systems - September 2008 - BACnet Supplement (Page 11B) Engineered Systems - September 2008 - BACnet Supplement (Page 12B) Engineered Systems - September 2008 - BACnet Supplement (Page 13B) Engineered Systems - September 2008 - BACnet Supplement (Page 14B) Engineered Systems - September 2008 - BACnet Supplement (Page 15B) Engineered Systems - September 2008 - BACnet Supplement (Page 16B) Engineered Systems - September 2008 - BACnet Supplement (Page 17B) Engineered Systems - September 2008 - BACnet Supplement (Page 18B) Engineered Systems - September 2008 - BACnet Supplement (Page 19B) Engineered Systems - September 2008 - BACnet Supplement (Page 20B) Engineered Systems - September 2008 - BACnet Supplement (Page 21B) Engineered Systems - September 2008 - Race To Market (Page 66) Engineered Systems - September 2008 - Race To Market (Page 67) Engineered Systems - September 2008 - Race To Market (Page 68) Engineered Systems - September 2008 - Race To Market (Page 69) Engineered Systems - September 2008 - Race To Market (Page 70) Engineered Systems - September 2008 - Race To Market (Page 71) Engineered Systems - September 2008 - Steam Humidification In Pharmaceutical Facilities (Page 72) Engineered Systems - September 2008 - Steam Humidification In Pharmaceutical Facilities (Page 73) Engineered Systems - September 2008 - Steam Humidification In Pharmaceutical Facilities (Page 74) Engineered Systems - September 2008 - Steam Humidification In Pharmaceutical Facilities (Page 75) Engineered Systems - September 2008 - Outside Air, Inside Data Centers (Page 76) Engineered Systems - September 2008 - Outside Air, Inside Data Centers (Page 77) Engineered Systems - September 2008 - Outside Air, Inside Data Centers (Page 78) Engineered Systems - September 2008 - Outside Air, Inside Data Centers (Page 79) Engineered Systems - September 2008 - Outside Air, Inside Data Centers (Page 80) Engineered Systems - September 2008 - Forecast: Increasingly Cloudy And Under Control (Page 81) Engineered Systems - September 2008 - Forecast: Increasingly Cloudy And Under Control (Page 82) Engineered Systems - September 2008 - Forecast: Increasingly Cloudy And Under Control (Page 83) Engineered Systems - September 2008 - Forecast: Increasingly Cloudy And Under Control (Page 84) Engineered Systems - September 2008 - Forecast: Increasingly Cloudy And Under Control (Page 85) Engineered Systems - September 2008 - Forecast: Increasingly Cloudy And Under Control (Page 86) Engineered Systems - September 2008 - Products (Page 87) Engineered Systems - September 2008 - Products (Page 88) Engineered Systems - September 2008 - Products (Page 89) Engineered Systems - September 2008 - Computers & Software (Page 90) Engineered Systems - September 2008 - Literature (Page 91) Engineered Systems - September 2008 - Glossary (Page 92) Engineered Systems - September 2008 - Classifieds (Page 93) Engineered Systems - September 2008 - Classifieds (Page 94) Engineered Systems - September 2008 - Classifieds (Page 95) Engineered Systems - September 2008 - Classifieds (Page 96) Engineered Systems - September 2008 - Advertiser Index (Page 97) Engineered Systems - September 2008 - Tomorrow's Environment (Page 98) Engineered Systems - September 2008 - Tomorrow's Environment (Page Cover3) Engineered Systems - September 2008 - Tomorrow's Environment (Page Cover4)
For optimal viewing of this digital publication, please enable JavaScript and then refresh the page. If you would like to try to load the digital publication without using Flash Player detection, please click here.