Drug Information Journal - March 2009 - (Page 147) Local Laboratory Reference Intervals MEDICAL INFORMATION 147 130 FIGURE 4 120 Empirical Lower Limit Relative to Central Laboratory URL (=100*expΛi ) Hemoglobin LRL relationship. 110 100 90 80 70 70 75 80 85 90 95 100 105 110 115 Lab Lower Limit Relative to Central Laboratory URL (=100*expL i ) from 175 to 96 and 46 respectively, the correlations and scatter plots were essentially identical. R E S U LT S In Figures 4 and 5, we provide examples for hemoglobin and serum creatinine respectively. The scatter plots of empirical LRL or URL (verti- cal axis) against the relevant actual limit (horizontal axis) indicate whether or not there is a population-based rationale for the choice of local reference limit. If there is a rational basis, the cloud of data points should show a marked trend from lower left to upper right (that is, a significant correla- 170 FIGURE 5 150 Empirical URL Relative to Central Laboratory URL (=100*expΛi ) Creatinine URL relationship. 130 110 90 70 50 50 60 70 80 90 100 110 120 130 140 Lab URL Relative to Central Laboratory URL (=100*expL i ) Drug Information Journal