NFPA Journal - November/December 2012 - (Page 40)

>>ELECTRICAL SAFETY NEC, NFPA 70E, ANd morE jeffrey sargent Keep It Clear Proposal for 2014 NEC would sharpen requirements for clear work space proposed requirement for the 2014 edition of the National Electrical Code® (NEC®) addresses the ongoing need to maintain clear working space around electrical equipment that is likely to be worked on while energized. Energized tasks on electrical equipment are inherently dangerous, and the new requirement is based on the need to give qualified workers the necessary space so that their safe access to the energized parts is ANY ELECTRICIAN who performs service work has stories about maneuvering around stored items. not compromised or impeded. An additional benefit of clear working space is that it provides the required ready access to overcurrent protective devices. The code currently requires clear access to energized electrical equipment for examination, adjustment, servicing, or maintenance, with adequate room to move freely and safely while performing energized tasks. Even though the energized tasks permitted by NFPA 70E®, Electrical Safety in the Workplace®, and OSHA’s General Industry Standard (29 CFR, Part 1910, Subpart S) are limited, they still require sufficient working space, which is an essential piece of the safe work equation. The proposed requirement would more clearly define the space that must remain clear. Code-Making Panel 1, through its action on Proposal 1-110, has accepted a recommendation that creates a new A requirement for marking the height, width, and depth of the working space for all equipment covered by the requirements of Sections 110.26(A) and 110.32. The marking is to be either on the equipment or immediately adjacent to it. Working space does not have a direct effect on the operation of the electrical system, though there may be instances with heat-producing equipment where the working space also provides necessary clearances for proper heat dissipation and ventilation. Therefore, its value is often only recognized by those in the electrical industry. To building owners, the space around this equipment can represent valuable square footage that could be used to generate additional revenue, and for building occupants, that “extra” space practically begs for something to be stored in it. Unless a building’s owner or management is actively involved in the building’s day-to-day operations after the occupancy permit has been granted, the requirement in Sections 110.26(B) and 110.34(A) calling for the working space to be clear and not used for storage can be easily overlooked. Any electrician who performs service work has plenty of stories about maneuvering around stored items or having to remove obstacles in order to perform necessary energized tasks, such as voltage testing or other diagnostic work. jeffrey sargent is a regional electrical code specialist for NFPA. 40 NFPA JOURNAL NOVEMBER/DECEMBER 2012 Illustration: Rob Dunlavey Despite being responsible for code compliance, many building owners and managers are unaware of the NEC working space requirements. In addition, building, fire, and electrical code enforcement officials who inspect buildings during construction do not typically perform ongoing inspections. Some occupancy types, such as places of assembly, education, and heath care, are subject to periodic inspections for systems and occupancy purposes, and it is this kind of ongoing inspection program that is usually necessary to enforce NEC working space requirements. In workplaces, that responsibility can fall to the building owner, property manager, or other legally responsible party. That is because 29 CFR, Part 1910, contains the clear working space requirements contained in Sections 110.26(A) and 110.32 of the NEC.

Table of Contents for the Digital Edition of NFPA Journal - November/December 2012

NFPA Journal - November/December 2012
Contents
First Word
In a Flash
Perspectives
Firewatch
Research
Heads Up
Structural Ops
In Compliance
Buzzwords
Outreach
Electrical Safety
Wildfire Watch
Past + Present
Easy Being Green?
Pressure Points
2011 Large-Loss Fires
2011 Firefighter Injuries
Section Spotlight
What’s Hot
Looking Back

NFPA Journal - November/December 2012

https://www.nxtbook.com/nxtbooks/nfpa/journal_2024spring
https://www.nxtbook.com/nxtbooks/nfpa/journal_2023winter
https://www.nxtbook.com/nxtbooks/nfpa/journal_2023fall
https://www.nxtbook.com/nxtbooks/nfpa/journal_2023summer
https://www.nxtbook.com/nxtbooks/nfpa/journal_2023spring
https://www.nxtbook.com/nxtbooks/nfpa/journal_2022winter
https://www.nxtbook.com/nxtbooks/nfpa/journal_2022fall
https://www.nxtbook.com/nxtbooks/nfpa/journal_2022summer
https://www.nxtbook.com/nxtbooks/nfpa/journal_2022spring
https://www.nxtbook.com/nxtbooks/nfpa/journal_2021winter
https://www.nxtbook.com/nxtbooks/nfpa/journal_2021fall
https://www.nxtbook.com/nxtbooks/nfpa/journal_2021summer
https://www.nxtbook.com/nxtbooks/nfpa/journal_2021spring
https://www.nxtbook.com/nxtbooks/nfpa/journal_20201112
https://www.nxtbook.com/nxtbooks/nfpa/journal_20200910
https://www.nxtbook.com/nxtbooks/nfpa/journal_20200708
https://www.nxtbook.com/nxtbooks/nfpa/journal_20200506
https://www.nxtbook.com/nxtbooks/nfpa/journal_20200304
https://www.nxtbook.com/nxtbooks/nfpa/journal_20200102
https://www.nxtbook.com/nxtbooks/nfpa/journal_20191112
https://www.nxtbook.com/nxtbooks/nfpa/journal_20190910
https://www.nxtbook.com/nxtbooks/nfpa/journal_20190708
https://www.nxtbook.com/nxtbooks/nfpa/journal_20190506
https://www.nxtbook.com/nxtbooks/nfpa/journal_20190304
https://www.nxtbook.com/nxtbooks/nfpa/journal_20190102
https://www.nxtbook.com/nxtbooks/nfpa/journal_20181112
https://www.nxtbook.com/nxtbooks/nfpa/journal_20180910
https://www.nxtbook.com/nxtbooks/nfpa/journal_20180708
https://www.nxtbook.com/nxtbooks/nfpa/journal_20180506
https://www.nxtbook.com/nxtbooks/nfpa/journal_20180304
https://www.nxtbook.com/nxtbooks/nfpa/journal_20180102
https://www.nxtbook.com/nxtbooks/nfpa/journal_20171112
https://www.nxtbook.com/nxtbooks/nfpa/journal_20170910
https://www.nxtbook.com/nxtbooks/nfpa/journal_20170708
https://www.nxtbook.com/nxtbooks/nfpa/journal_20170506
https://www.nxtbook.com/nxtbooks/nfpa/journal_20170304
https://www.nxtbook.com/nxtbooks/nfpa/journal_20170102
https://www.nxtbook.com/nxtbooks/nfpa/journal_20161112
https://www.nxtbook.com/nxtbooks/nfpa/journal_201610_sprinkler
https://www.nxtbook.com/nxtbooks/nfpa/journal_20160910
https://www.nxtbook.com/nxtbooks/nfpa/journal_20160708
https://www.nxtbook.com/nxtbooks/nfpa/journal_20160506
https://www.nxtbook.com/nxtbooks/nfpa/journal_20160304
https://www.nxtbook.com/nxtbooks/nfpa/journal_20160102
https://www.nxtbook.com/nxtbooks/nfpa/journal_20151112
https://www.nxtbook.com/nxtbooks/nfpa/journal_20150910
https://www.nxtbook.com/nxtbooks/nfpa/journal_20150708
https://www.nxtbook.com/nxtbooks/nfpa/journal_20150506
https://www.nxtbook.com/nxtbooks/nfpa/journal_20150304
https://www.nxtbook.com/nxtbooks/nfpa/journal_201501
https://www.nxtbook.com/nxtbooks/nfpa/journal_20141112
https://www.nxtbook.com/nxtbooks/nfpa/journal_20140910
https://www.nxtbook.com/nxtbooks/nfpa/journal_20140708
https://www.nxtbook.com/nxtbooks/nfpa/journal_20140506
https://www.nxtbook.com/nxtbooks/nfpa/journal_20140304
https://www.nxtbook.com/nxtbooks/nfpa/journal_20140102
https://www.nxtbook.com/nxtbooks/nfpa/journal_20131112
https://www.nxtbook.com/nxtbooks/nfpa/journal_20130910
https://www.nxtbook.com/nxtbooks/nfpa/journal_20130708
https://www.nxtbook.com/nxtbooks/nfpa/journal_20130506
https://www.nxtbook.com/nxtbooks/nfpa/journal_20130304
https://www.nxtbook.com/nxtbooks/nfpa/journal_20130102
https://www.nxtbook.com/nxtbooks/nfpa/journal_20121112
https://www.nxtbook.com/nxtbooks/nfpa/journal_20120910
https://www.nxtbook.com/nxtbooks/nfpa/journal_20120708
https://www.nxtbook.com/nxtbooks/nfpa/journal_20120506
https://www.nxtbook.com/nxtbooks/nfpa/journal_20120304
https://www.nxtbookmedia.com