Compressed Air Best Practices - January 2009 - (Page 32) | 01/09 Focus Industry ENERGY REBATES | M I N I M U M S U P P LY W I R E S I Z E R E C O M M E N D A T I O N S F O R C O M P R E S S O R PA C K A G E S U T I L I Z I N G VA R I A B L E F R E Q U E N C Y D R I V E S Based on the example above, if a wire run length of 100 feet of 75 ºC copper wire is used and all terminal connection points are rated for a minimum of 75 ºC, then copper wire size number 1 AWG can be used for this application as it is rated for 130A at 30 ºC ambient which meets the minimum package conductor amperage requirement of 125A. Keep in mind that the length of the wire run to the compressor is important as it directly affects voltage drop. Most drive applications utilize 40 ºC or 45 ºC for ambient temperature conditions. These conditions require conductor ampacity correction(s) to allow for the higher temperatures. The NEC requires that conductor sizes for use in other than 30 ºC ambient temperature be determined by using the appropriate multiplier listed at the bottom section of NEC Table 310.16, and selecting the conductor size that has sufficient ampacity, after correction(s), to meet the load requirements. Conductor ampacity is to be corrected, not “Package Amps.” An example of this procedure, utilizing the example shown above, is as follows: p The 1 AWG copper conductors referenced, above, are rated for 130 amperes based on an ambient temperature of 30 ºC and a conductor temperature rating of 75 ºC. For 40 ºC ambient conditions, the 75 ºC conductor ampacity correction factor is 0.88 resulting in the 1 AWG copper conductor ampacity being corrected from 130 amperes at 30 ºC to 114.4 (130 x .88) amperes at 40 ºC ambient. Number 1 AWG wire is not sufficient for this application at 40 ºC because the corrected conductor ampacity is less than the required minimum of 125 amperes. For 45 ºC ambient conditions, the 75 ºC conductor ampacity correction factor is 0.82 resulting in the 1 AWG copper conductor ampacity being corrected from 130 amperes at 30 ºC to 106.6 (130 x .82) amperes at 45 ºC ambient. Number 1 AWG wire is not sufficient for this application at 45 ºC because the corrected conductor ampacity is less than the required minimum of 125 amperes. p p 32 www.airbestpractices.com http://www.airbestpractices.com
Table of Contents Feed for the Digital Edition of Compressed Air Best Practices - January 2009 Compressed Air Best Practices - January 2009 Contents From the Editor Utility-Air News Compressed Air Audit of the Month: A Nitrogen Audit at Boeing Air Standards: New ASME & ISO Standards for Compressed Air System Assessments Energy Rebates Assist Industrial Sustainability Initiatives Seven Sustainability Projects for Industrial Energy Savings: Project #1: Lighting Optimization Minimum Supply Wire Size Recommendations for Compressor Packages Utilizing Variable Frequency Drives The Pneumatic Advantage: Pneumatics Bring Precision and Reliability to Furniture Industry Specialist Personal Productivity: Is Afternoon Fatigue Influencing Your Job Performance? The Explanation and Some Solutions. Resources for Energy Engineers: Training Calendar & Product Picks Wall Street Watch Advertiser Index Classifieds Compressed Air Best Practices - January 2009 Compressed Air Best Practices - January 2009 - Compressed Air Best Practices - January 2009 (Page Cover1) Compressed Air Best Practices - January 2009 - Compressed Air Best Practices - January 2009 (Page Cover2) Compressed Air Best Practices - January 2009 - Compressed Air Best Practices - January 2009 (Page 3) Compressed Air Best Practices - January 2009 - Contents (Page 4) Compressed Air Best Practices - January 2009 - Contents (Page 5) Compressed Air Best Practices - January 2009 - From the Editor (Page 6) Compressed Air Best Practices - January 2009 - Utility-Air News (Page 7) Compressed Air Best Practices - January 2009 - Utility-Air News (Page 8) Compressed Air Best Practices - January 2009 - Utility-Air News (Page 9) Compressed Air Best Practices - January 2009 - Compressed Air Audit of the Month: A Nitrogen Audit at Boeing (Page 10) Compressed Air Best Practices - January 2009 - Compressed Air Audit of the Month: A Nitrogen Audit at Boeing (Page 11) Compressed Air Best Practices - January 2009 - Compressed Air Audit of the Month: A Nitrogen Audit at Boeing (Page 12) Compressed Air Best Practices - January 2009 - Compressed Air Audit of the Month: A Nitrogen Audit at Boeing (Page 13) Compressed Air Best Practices - January 2009 - Compressed Air Audit of the Month: A Nitrogen Audit at Boeing (Page 14) Compressed Air Best Practices - January 2009 - Compressed Air Audit of the Month: A Nitrogen Audit at Boeing (Page 15) Compressed Air Best Practices - January 2009 - Air Standards: New ASME & ISO Standards for Compressed Air System Assessments (Page 16) Compressed Air Best Practices - January 2009 - Air Standards: New ASME & ISO Standards for Compressed Air System Assessments (Page 17) Compressed Air Best Practices - January 2009 - Air Standards: New ASME & ISO Standards for Compressed Air System Assessments (Page 18) Compressed Air Best Practices - January 2009 - Energy Rebates Assist Industrial Sustainability Initiatives (Page 19) Compressed Air Best Practices - January 2009 - Energy Rebates Assist Industrial Sustainability Initiatives (Page 20) Compressed Air Best Practices - January 2009 - Energy Rebates Assist Industrial Sustainability Initiatives (Page 21) Compressed Air Best Practices - January 2009 - Energy Rebates Assist Industrial Sustainability Initiatives (Page 22) Compressed Air Best Practices - January 2009 - Energy Rebates Assist Industrial Sustainability Initiatives (Page 23) Compressed Air Best Practices - January 2009 - Energy Rebates Assist Industrial Sustainability Initiatives (Page 24) Compressed Air Best Practices - January 2009 - Seven Sustainability Projects for Industrial Energy Savings: Project #1: Lighting Optimization (Page 25) Compressed Air Best Practices - January 2009 - Seven Sustainability Projects for Industrial Energy Savings: Project #1: Lighting Optimization (Page 26) Compressed Air Best Practices - January 2009 - Seven Sustainability Projects for Industrial Energy Savings: Project #1: Lighting Optimization (Page 27) Compressed Air Best Practices - January 2009 - Seven Sustainability Projects for Industrial Energy Savings: Project #1: Lighting Optimization (Page 28) Compressed Air Best Practices - January 2009 - Seven Sustainability Projects for Industrial Energy Savings: Project #1: Lighting Optimization (Page 29) Compressed Air Best Practices - January 2009 - Seven Sustainability Projects for Industrial Energy Savings: Project #1: Lighting Optimization (Page 30) Compressed Air Best Practices - January 2009 - Minimum Supply Wire Size Recommendations for Compressor Packages Utilizing Variable Frequency Drives (Page 31) Compressed Air Best Practices - January 2009 - Minimum Supply Wire Size Recommendations for Compressor Packages Utilizing Variable Frequency Drives (Page 32) Compressed Air Best Practices - January 2009 - Minimum Supply Wire Size Recommendations for Compressor Packages Utilizing Variable Frequency Drives (Page 33) Compressed Air Best Practices - January 2009 - Minimum Supply Wire Size Recommendations for Compressor Packages Utilizing Variable Frequency Drives (Page 34) Compressed Air Best Practices - January 2009 - The Pneumatic Advantage: Pneumatics Bring Precision and Reliability to Furniture Industry Specialist (Page 35) Compressed Air Best Practices - January 2009 - The Pneumatic Advantage: Pneumatics Bring Precision and Reliability to Furniture Industry Specialist (Page 36) Compressed Air Best Practices - January 2009 - The Pneumatic Advantage: Pneumatics Bring Precision and Reliability to Furniture Industry Specialist (Page 37) Compressed Air Best Practices - January 2009 - Personal Productivity: Is Afternoon Fatigue Influencing Your Job Performance? The Explanation and Some Solutions. (Page 38) Compressed Air Best Practices - January 2009 - Personal Productivity: Is Afternoon Fatigue Influencing Your Job Performance? The Explanation and Some Solutions. (Page 39) Compressed Air Best Practices - January 2009 - Personal Productivity: Is Afternoon Fatigue Influencing Your Job Performance? The Explanation and Some Solutions. (Page 40) Compressed Air Best Practices - January 2009 - Resources for Energy Engineers: Training Calendar & Product Picks (Page 41) Compressed Air Best Practices - January 2009 - Resources for Energy Engineers: Training Calendar & Product Picks (Page 42) Compressed Air Best Practices - January 2009 - Resources for Energy Engineers: Training Calendar & Product Picks (Page 43) Compressed Air Best Practices - January 2009 - Wall Street Watch (Page 44) Compressed Air Best Practices - January 2009 - Wall Street Watch (Page 45) Compressed Air Best Practices - January 2009 - Wall Street Watch (Page 46) Compressed Air Best Practices - January 2009 - Wall Street Watch (Page 47) Compressed Air Best Practices - January 2009 - Wall Street Watch (Page 48) Compressed Air Best Practices - January 2009 - Advertiser Index (Page 49) Compressed Air Best Practices - January 2009 - Classifieds (Page 50) Compressed Air Best Practices - January 2009 - Classifieds (Page Cover3) Compressed Air Best Practices - January 2009 - Classifieds (Page Cover4)
For optimal viewing of this digital publication, please enable JavaScript and then refresh the page. If you would like to try to load the digital publication without using Flash Player detection, please click here.