Best Practice Guide for Office Buildings - (Page 12) OFFICE Campus BUILDINGS OF-B2.0 Building Campus: network communication • software access Control Needs Shared lighting control data across multiple floors and multiple buildings Centralized control, programming, monitoring, trending, and reporting of lighting control system Graphical display of lighting control status matching facility layout Web-based access to lighting control network Solution Networked lighting control panels (Lighting Integrator Complete Control level) Lighting control software to operate on facility manager’s PC (WinControl software package) Graphics based lighting control software package (WinControl Graphics) Browser-based control via WebLink Application Description Five-building office campus with three stories per building. Includes parking lots, walkways, driveways, courtyards and signs. Underground conduit system provides access between buildings and exterior lighting. All security, building automation, fire alarm and lighting control systems to be monitored and controlled from facility manager’s office on the first floor of building 1. Building Requirements Requires lighting control panels on each building floor with no more than 24 relays per panel. Power for lighting control panels is 277 VAC. Refer to individual office plan solutions for specific information on individual space and exterior lighting requirements. Business Lighting Plan Building 1 Building 2,3,4,5 C HPSA Photocell Third Floor LCPX-3 Third Floor LCP1-3 A B A A C Network dataline wire Low voltage wire Sensor wire Dataline Link WEB Link Lighting Control Panel Second Floor LCPX-2 Second Floor LCP1-2 HLINKCC WL-Base LCP A A C First Floor LCPX-1 First Floor LCP1-1 Typical occupancy sensor (as needed) Typical cleaning switch, 1 per wing (as needed) B Typical low voltage switch (as needed) B HLINKCC HLINKCC WL-Base WL-Base Central Administration PC Ethernet LAN to Central Administration PC Design Solution Description Lighting Integrator Complete Control lighting control panels on each floor and between each building are networked together by dataline wire. Each panel communicates lighting control activity over the dataline. A riser diagram indicates the wiring required between each panel and lighting control device in the system. A dataline power supply and network options module (HDPS1CC) powers the dataline and a dataline link (HLINKCC) connects the dataline to the PC in the facility manager’s office in building 1. WinControl and WinControl Graphics software packages allow the manager to see the lighting activity in all areas controlled by the lighting control panels. Scheduling and control programming can be performed at the facility manager’s office and downloaded over the dataline to the lighting control panels, or performed remotely via web browser using WebLink. 12 Watt Stopper/Legrand OF-B2.0 0908
Table of Contents Feed for the Digital Edition of Best Practice Guide for Office Buildings Best Practice Guide for Office Buildings Contents Lighting Control Best Practice Guide for Office Buildings Value of Lighting Control for Office Buildings Office Building Space Usage Influential Factors for Lighting Control Office Building Lighting Control Design Guidelines Office Building Best Practice Guide Roadmap Summary of Best Practices for Lighting Control in Office Buildings Buildings Conference Rooms Cubicles Hallways Kitchens Open Offices Private Offices Restrooms Stairwells Storage Closets Exterior Lighting Summary of Energy Codes Best Practice Guide for Office Buildings Best Practice Guide for Office Buildings - Best Practice Guide for Office Buildings (Page 1) Best Practice Guide for Office Buildings - Contents (Page 2) Best Practice Guide for Office Buildings - Lighting Control Best Practice Guide for Office Buildings (Page 3) Best Practice Guide for Office Buildings - Office Building Space Usage (Page 4) Best Practice Guide for Office Buildings - Influential Factors for Lighting Control (Page 5) Best Practice Guide for Office Buildings - Office Building Lighting Control Design Guidelines (Page 6) Best Practice Guide for Office Buildings - Office Building Lighting Control Design Guidelines (Page 7) Best Practice Guide for Office Buildings - Office Building Best Practice Guide Roadmap (Page 8) Best Practice Guide for Office Buildings - Summary of Best Practices for Lighting Control in Office Buildings (Page 9) Best Practice Guide for Office Buildings - Buildings (Page 10) Best Practice Guide for Office Buildings - Buildings (Page 11) Best Practice Guide for Office Buildings - Buildings (Page 12) Best Practice Guide for Office Buildings - Buildings (Page 13) Best Practice Guide for Office Buildings - Conference Rooms (Page 14) Best Practice Guide for Office Buildings - Conference Rooms (Page 15) Best Practice Guide for Office Buildings - Conference Rooms (Page 16) Best Practice Guide for Office Buildings - Conference Rooms (Page 17) Best Practice Guide for Office Buildings - Conference Rooms (Page 18) Best Practice Guide for Office Buildings - Conference Rooms (Page 19) Best Practice Guide for Office Buildings - Cubicles (Page 20) Best Practice Guide for Office Buildings - Cubicles (Page 21) Best Practice Guide for Office Buildings - Hallways (Page 22) Best Practice Guide for Office Buildings - Hallways (Page 23) Best Practice Guide for Office Buildings - Hallways (Page 24) Best Practice Guide for Office Buildings - Hallways (Page 25) Best Practice Guide for Office Buildings - Hallways (Page 26) Best Practice Guide for Office Buildings - Hallways (Page 27) Best Practice Guide for Office Buildings - Kitchens (Page 28) Best Practice Guide for Office Buildings - Kitchens (Page 29) Best Practice Guide for Office Buildings - Open Offices (Page 30) Best Practice Guide for Office Buildings - Open Offices (Page 31) Best Practice Guide for Office Buildings - Open Offices (Page 32) Best Practice Guide for Office Buildings - Open Offices (Page 33) Best Practice Guide for Office Buildings - Open Offices (Page 34) Best Practice Guide for Office Buildings - Open Offices (Page 35) Best Practice Guide for Office Buildings - Open Offices (Page 36) Best Practice Guide for Office Buildings - Open Offices (Page 37) Best Practice Guide for Office Buildings - Open Offices (Page 38) Best Practice Guide for Office Buildings - Open Offices (Page 39) Best Practice Guide for Office Buildings - Open Offices (Page 40) Best Practice Guide for Office Buildings - Open Offices (Page 41) Best Practice Guide for Office Buildings - Open Offices (Page 42) Best Practice Guide for Office Buildings - Open Offices (Page 43) Best Practice Guide for Office Buildings - Open Offices (Page 44) Best Practice Guide for Office Buildings - Open Offices (Page 45) Best Practice Guide for Office Buildings - Open Offices (Page 46) Best Practice Guide for Office Buildings - Open Offices (Page 47) Best Practice Guide for Office Buildings - Open Offices (Page 48) Best Practice Guide for Office Buildings - Open Offices (Page 49) Best Practice Guide for Office Buildings - Open Offices (Page 50) Best Practice Guide for Office Buildings - Open Offices (Page 51) Best Practice Guide for Office Buildings - Private Offices (Page 52) Best Practice Guide for Office Buildings - Private Offices (Page 53) Best Practice Guide for Office Buildings - Private Offices (Page 54) Best Practice Guide for Office Buildings - Private Offices (Page 55) Best Practice Guide for Office Buildings - Private Offices (Page 56) Best Practice Guide for Office Buildings - Private Offices (Page 57) Best Practice Guide for Office Buildings - Private Offices (Page 58) Best Practice Guide for Office Buildings - Private Offices (Page 59) Best Practice Guide for Office Buildings - Private Offices (Page 60) Best Practice Guide for Office Buildings - Private Offices (Page 61) Best Practice Guide for Office Buildings - Restrooms (Page 62) Best Practice Guide for Office Buildings - Restrooms (Page 63) Best Practice Guide for Office Buildings - Restrooms (Page 64) Best Practice Guide for Office Buildings - Restrooms (Page 65) Best Practice Guide for Office Buildings - Stairwells (Page 66) Best Practice Guide for Office Buildings - Stairwells (Page 67) Best Practice Guide for Office Buildings - Stairwells (Page 68) Best Practice Guide for Office Buildings - Stairwells (Page 69) Best Practice Guide for Office Buildings - Storage Closets (Page 70) Best Practice Guide for Office Buildings - Storage Closets (Page 71) Best Practice Guide for Office Buildings - Exterior Lighting (Page 72) Best Practice Guide for Office Buildings - Exterior Lighting (Page 73) Best Practice Guide for Office Buildings - Exterior Lighting (Page 74) Best Practice Guide for Office Buildings - Exterior Lighting (Page 75) Best Practice Guide for Office Buildings - Summary of Energy Codes (Page 76) Best Practice Guide for Office Buildings - Summary of Energy Codes (Page 77) Best Practice Guide for Office Buildings - Summary of Energy Codes (Page 78)
For optimal viewing of this digital publication, please enable JavaScript and then refresh the page. If you would like to try to load the digital publication without using Flash Player detection, please click here.