SPUTTERED THIN FILM Wire & Cable Options Cable 1/2˝ Conduit Connection Flying Lead BLACK WHITE RED BLACK GREEN WHITE RED 24 AWG CABLE (PVC) GREEN CABLE GLAND 24 AWG CABLE (PVC) BLACK CABLE GLAND RED 1/2 NPT 2.4 (60.1) 2.0 (50.8) WHITE 26 AWG WIRE (TEFLON®) 1˝ HEX 1.0 (25.4) inch (mm) Code F Code 3 Code W Wire Color Voltage Mode Current Mode Voltage Mode Current Mode Voltage Mode Current Mode Red +IN +IN +IN +IN +IN +IN Black 0V 0V 0V 0V 0V 0V White Vout1 (pressure) Do Not Connect Vout1 (pressure) Do Not Connect Vout Do Not Connect Green PE or Vout2 (temp)* PE PE or Vout2 (temp)* PE - - *This pin is used for temperature sensing output when this option is utilized. Otherwise, the pin is used for PE. Wiring Diagram Current Output Mode (Load Resistor Range) 1200 COMMON (-) (+) OUT(+) VOLTAGE OUTPUT TRANSDUCER READOUT POWER SUPPLY (-) (+) (-) + (+) (-) CURRENT OUTPUT TRANSDUCER 1100 1000 900 MAXIMUM RESISTOR (RL) 800 700 600 500 400 300 MINIMUM RESISTOR (RL) 200 100 0 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 CUSTOMER SUPPLY VOLTAGE (V) READOUT Minimum Resistor Value = 50*(+V - 24) for +V > 24V Maximum Resistor Value = 50*(+V - 8) for +V > 8V PRESSURE TRANSDUCERS IN (+) CUSTOMER LOAD RESISTOR (OHMS) POWER SUPPLY (-) (+) Note: Mating connectors available upon request - contact factory. 3100-3200 Series / p4of5 / 20-AUG-19 Visit www.GemsSensors.com for most current information. H-33http://www.GemsSensors.com