YOV SSG Vent Window PROJECT OUT w/ VENT MULTIPOINT LOCK 1. SIZE LIMITATIONS: (Based on AW-70 & AW-100 Designation) VENT WIDTH A B HP SNUBBERS - H-1901 (AW-100) SNUBBERS - E3-1103 (AW-70) VENT HEIGHT MINIMUM SIZE 21-1/2 " [546.1mm] 41 " [1041.4mm] 2.4 sq. ft. 15-3/4 " [400.0mm] 50 " [1270.0mm] MAXIMUM SIZE 16.4 sq. ft. (Based on 70 psf and listed hardware) 3 SNUBBERS * (2 AT 1/4 POINTS, 1 ON CENTER) C D 2 SNUBBERS 62 " [1574.8mm] 74 " [1879.6mm] 38 " [965.2mm] 31 " [787.4mm] * Indicates size as tested (2 AT 1/4 POINTS) 1 SNUBBER (1 ON CENTER) B 50 " 48 " APPROVED SIZES C TESTED SIZE LOCK POINT SNUBBER D 24 " A 24 " 21-1/2 " 15-3/4 " 11 " Max. (AW-100 Only) 11 " Max. (AW-100 Only) VENT HEIGHT 38 " 36 " 36 " 21-1/16 " Max 48 " 21-1/16 " Max 60 " 62 " 72 " 74 " 21-1/16 " Max VENT LOCK POINTS (Min Width = 21-1/2 " ) VENT WIDTH 2. FLORIDA PRODUCT APPROVED *NON-IMPACT* Page-46 05-1018-06 | Effective Date: October 16, 2020