YOW 225 TU Operable Window System ACCESSIBLE WINDOW CASEMENT OUTSWING 1. SIZE LIMITATIONS: (Based on AW-65 & DP-45 Designation. Meets AAMA 513-14 Forces and Motion for Windows in Accessible Spaces.) VENT WIDTH A B VENT HEIGHT MINIMUM SIZE (BUTT HINGE ONLY) 14-1/8 " [358.8mm] 17-1/4 " [438.2mm] MINIMUM SIZE (4-BAR HINGE ONLY) 25 " [635.0mm] * * * D E F APPROVED SIZES 36 " [914.4mm] 37 " [939.8mm] C TESTED SIZE 35 " [889.0mm] G 38 " [965.2mm] * H MAXIMUM SIZE 37 " [939.8mm] 17-1/4 " [438.2mm] VENT AREA 1.7 sq. ft. 3.0 sq. ft. 63-1/8 " [1603.4mm] 15.7 sq. ft. 17.2 sq. ft 67 " [1701.8mm] 37-1/2 " [952.5mm] 71-1/4 " [1809.8mm] 18.6 sq. ft 59 " [1498.6mm] 76 " [1930.4mm] 78 " [1981.2mm] LOCK JAMB 78 " 72 " 59 " H G E F D 60 " C * Approved size for pressure requirments, not AW rated. 48 " 35.2 " 36 " 14.3 sq. ft. 20.1 sq. ft. 20.0 sq. ft. ALLOWABLE DESIGN PRESSURE 65 psf 65 psf 60 psf 55 psf 50 psf 65 psf 45 psf 45 psf HINGE JAMB Notes: See Tech Drawings for vent size restrictions when using 4-Bar Hinges. NYC limit devices available with butt hinges only 24 " A 12 " B LOCK POINT 12 " 24 " 36 " VENT WIDTH w/ ROTARY OPERATOR Effective Date: June 2, 2021 | 05-1003-12 Page-35 4 PT. LOCK ZONE 3 PT. LOCK ZONE 2 PT. LOCK ZONE 6.3 " VENT HEIGHT 4-BAR OR BUTT HINGES