YOW 225 TU/TUH Operable Window System CASEMENT OUTSWING 1. SIZE LIMITATIONS: (Based on Florida Product Approvals) 12" 4BAR HINGE VENT WIDTH MINIMUM SIZE 14" [355.6mm] 16" 4BAR HINGE VENT HEIGHT 14" [355.6mm] When using Multi Lock or Butt Hinges 14" [355.6mm] 24" [355.6mm] BUTT HINGES ONLY MAXIMUM SIZE (±65 PSF) 36-1/8" [917.6mm] 72" [1828.8mm] When using Multi Lock and Butt Hinges 48" [917.6mm] 72" [1828.8mm] MAXIMUM SIZE (±80 PSF) (requires Multi Lock) 42" [1066.8mm] 72" [1828.8mm] SNUBBER SCHEDULE 2. HARDWARE LOCATIONS Varies MULTI-POINT LOCK Number of Required Snubbers At Hinge Jamb Vent Height 4 72" ≥ H > 54" 3 54" ≥ H > 30" 2 30" ≥ H > 18" 1 18" ≥ H 9-1/2" Varies BUTT HINGE SCHEDULE Number of Required Butt Hinges Vent Height 3 72" ≥ H > 44" 2 44" ≥ H MULTI-POINT SCHEDULE 3. FOUR BAR HINGE USAGE E1-1957 12" Egress ≤ 36" [914.4mm] 165lbs [74.8kg] 90º 4K-14208 16" > 24" [609.6mm] 117lbs [53.0kg] 90º Page-70 Number of Required Lock Engagements Vent Height 4 72" ≥ H > 58-1/2" 3 58-1/2" ≥ H > 30" 2 30" ≥ H 05-1003-11 | Effective Date: October 1, 2020