YOW 350 T Technical Notes CASEMENT WITH CAM HANDLE 1. SIZE LIMITATIONS: (Based on AW-80 Designation) 24" 26" 30" 14" 36" 42" B 6' 72" 5' 60" A 3 VENT HEIGHT (FEET) 4-Bar Hinge Maximum Vent Height VENT HEIGHT MINIMUM SIZE 14" [355.6mm] 14" [355.6mm] When using Butt Hinges 24" [609.6mm] 14" [355.6mm] 54" 2 4' VENT WIDTH MAXIMUM SIZE 42" [1066.8mm] B 45" 38" 3' 2 Butt Hinge Minimum Vent Height LOCK POINTS 32" 2 2' 72" [1828.8mm] 28" 1 24" 2 3 1 HINGE TYPE 1 LOCK POINT 2 LOCK POINTS 3 LOCK POINTS 4 5 6 12" FOUR BAR 16" FOUR BAR BUTT HINGE 14" 1' TWO BUTT HINGES ONLY A 1' 0 6 5 4 2' THREE BUTT HINGES ONLY 3' VENT WIDTH (FEET) 2. HARDWARE LOCATIONS FW CL FH FH CL CAM HANDLE 1 POINT LOCK 8" [203.2mm] CAM HANDLE 2 POINT LOCK 8" [203.2mm] FH CAM HANDLE 3 POINT LOCK CL FW FW 3. FOUR BAR HINGE USAGE Page-54 PART NO. LENGTH VENT WIDTH MAX. WEIGHT MAX. OPENING ANGLE 4K-14207 12" [ 24" [609.6mm] 83lbs [38kg] 90° 4K-14208 16" $24" [609.6mm] 117lbs [53kg] 90° : LOCK LOCATION 05-1007-15 | Effective Date: October 1, 2020