YOW 225 Technical Notes PROJECT IN 1. SIZE LIMITATIONS: (Based on AW-65 Designation)* 22 " 4BAR HINGE (OPTIONAL) 38 " [965.2mm] 36 " [914.4mm] 30 " 24 " 12 " 4BAR HINGE 12 " 14 " A 24 " 12 " 14 " [355.6mm] 36 " 45 " [1143mm] VENT WIDTH (IN) 1 PT. LOCK ZONE CAM LOCKS 2 PT. LOCK ZONE MAXIMUM SQUARE FOOTAGE FOR ±65 PSF = 15 SQ. FT. 48 " [1,574.8mm] 60 " 62 " ONE CAM LOCK LIMITS 45 " [1,143mm] 38 " [965.2mm] 32 " [812.8mm] 24 " [609.6mm] 24 " [609.6mm] 28 " [711.2mm] 34 " [863.6mm] 38 " [965.2mm] APPROVED SIZES B C TESTED SIZE 16 " 5BAR HINGE A B C MINIMUM SIZE VENT WIDTH MAXIMUM SIZE 14 " [355.6mm] VENT HEIGHT 14 " [355.6mm] 56-3/4 " [1,441.5mm] 38 " [965.2mm] MAXIMUM SIZE 62 " [1,574.8mm] 34-3/4 " [882.7mm] APPROVED SIZE FOR PRESSURE REQUIREMENTS, NOT AW RATED ONE CAM LOCK LIMITS TESTED SIZE 2. FOUR BAR HINGE USAGE 4K-14207 5K-15284 4K-14209 12 " 16 " 22 " ≤ 24 " [609.6mm] > 24 " [609.6mm] > 30 " [762.0mm] Effective Date: April 25, 2024 | 05-1002-14 90 lbs [40.8kg] 130 lbs [59.0kg] 140 lbs [63.5kg] 20º w/ Limit Stop 30º w/o Limit Stop 45º w/ Limit Stop Page-37 VENT HEIGHT (IN)