YOW 350 T Technical Notes 1. SIZE LIMITATIONS: (Based on AW-80 Designation) CASEMENT WITH CAM HANDLE 24 " 14 " 6' 5' 3 4-Bar Hinge Maximum Vent Height 4' 3' 2 Butt Hinge Minimum Vent Height 2' 1 1' 14 " A 4 1' 2' 2. HARDWARE LOCATIONS CAM HANDLE 3POINT LOCK CAM HANDLE 2 POINT LOCK CAM HANDLE 1 POINT LOCK 5 3' VENTWIDTH (FEET) 6 TWO BUTT HINGES ONLY THREE BUTT HINGES ONLY 2 2 B 45 " 38 " 32 " 28 " 24 " 1 2 3 26 " 30 " 36 " 42 " B 72 " A 54 " 60 " VENT WIDTH MINIMUM SIZE 14 " [355.6mm] MAXIMUM SIZE 42 " [1066.8mm] LOCK POINTS 1 LOCK POINT 2 LOCK POINTS 3 LOCK POINTS 4 5 6 When using Butt Hinges 14 " [355.6mm] VENT HEIGHT 14 " [355.6mm] 24 " [609.6mm] 72 " [1828.8mm] HINGE TYPE 12 " FOUR BAR 16 " FOUR BAR BUTT HINGE CL CL CL FW FW 3. FOUR BAR HINGE USAGE PART NO. 4K-14207 4K-14208 Page-54 LENGTH 12 " 16 " VENT WIDTH 24 " [609.6mm] 624 " [609.6mm] MAX. WEIGHT 83lbs [38kg] 117lbs [53kg] MAX. OPENING ANGLE 90° 90° 05-1007-19 | Effective Date: July 8, 2024 : LOCK LOCATION FW FH VENT HEIGHT (FEET) 8 " [203.2mm] FH 8 " [203.2mm] FH