Accessories Cutting Glasliner FRP for Floor to Ceiling Heights of 8 Feet or Less: * Subtract 1/2" from height measurement to allow for expansion. * Allow for 1/8" expansion gap around pipes and other projections. Inside Corner End Cap Divider Bar Outside Corner Outside Corner Angle Nylon Rivets Drilling Fastener Holes: * Pre-drill fastener holes before applying adhesive. * Fastener holes should be slightly oversize to allow for normal expansion and contraction. * Drill holes no further than 8" apart and 1" from outside edge, 16" apart on intermediate and on 16" centers. FRP Adhesive Installation reminders: 1. Follow safety and fire guidelines during installation and use of panels. 2. First panel installed should be set true with plumb line. 3. Wall must be clean and flat. 4. Use moldings, silicone, nylon rivets and adhesive for best installation. 5. Apply adhesive per manufacturer's instructions. 6. Install panels and moldings. 7. Seal edges and moldings. 8. Remove excess silicone. 9. Clean panels after installation with light detergent. 800-238-5546 Allows new FRP panels to be applied over existing FRP panels Applying Adhesive * For best installation, combine adhesive and nylon fasteners. * Glasliner FRP should never be installed on uneven walls using only adhesive. Actual requirements may vary. Call Glasteel for complete installation instructions. www.glasteel.comhttp://www.glasteel.com