LOOSE TUBE Adventum® Indoor/Outdoor Loose Tube Plenum Rated -40˚C 75˚C MAX 432F TEMPERATURE RATING Operation -40°C to +75°C Storage -60°C tothe +85°C anywhere in a network, bypassing traditional transition points Place Adventum Installation +60°Ctraditional OSP cables. required in most installations, saving significant-20°C costtoover ® Sample Part Number: LTP12B048FB3010/F5 FLAME RATING Indoor/Outdoor | Up to 432 fibers | Plenum Rated | Totally dry construction Plenum OFNP/FT6 * Plenum rating enables installation to go directly * No transition point required, available in riser and from outside plant to riser shaft with no plenum rated transition points * Greatly reduced installation time and cost because * Cable core and buffer tubes use dry there is no cleaning of gels required for installation water-blocking technology * System grounding requirements are eliminated Indoor/Outdoor | Up to 432 fibers | Plenum Rated |(for Totally dry construction * Interlocking armor designs available non-armored versions) * Suitable for conduit or in-tray installations * Plenum rating enables installation to go directly from * Greatly reduced installation time and cost because outside plant to riser shaft with no transition points there is no cleaning of gels required for installation * Cable core and buffer tubes use dry * System grounding requirements are eliminated water-blocking technology (for non-armored versions) * Interlocking armor designs available * Suitable for conduit or in-tray installations * No transition point required PLENUM (OFNP) RATED TECHNICAL DATA - PHYSICAL Fibers Part Number Prefix 6 Diameter Install Weight Long Term Install Min. Bend Radius lb./kft. kg/km Long Term Max. Loading in. mm in. cm in. cm lb. N lb. N LTP006 0.260 6.6 30 45 3.9 9.9 2.6 6.6 300 1335 90 400 12 LTP012 0.260 6.6 33 49 3.9 9.9 2.6 6.6 300 1335 90 400 24 LTP12B024 0.370 9.4 55 82 5.6 14.1 3.7 9.4 300 1335 90 400 48 LTP12B048 0.370 9.4 56 83 5.6 14.1 3.7 9.4 300 1335 90 400 72 LTP12B072 0.460 11.7 80 119 6.9 17.5 4.6 11.7 600 2670 200 890 144 LTP12B144 0.670 17.0 209 311 10.1 25.5 6.7 17.0 1000 4448 300 1335 432 LTP12B432 0.940 23.9 362 539 14.1 35.8 9.4 23.9 1000 4448 300 1335 This is a representative part number listing. For part number details, refer to page 69. If HPD or PEP certification is required, additional lead time may be needed. For details, please contact us at 1-800-BERK-TEK. PAGE 126 | berktek.com 88 | berktek.com Berk-Tek reserves the right to change product numbers and/or product specifications at any time. Berk-Tek reserves the right to change product numbers and/or product specifications at any time.http://www.berktek.us/eservice/US-en_US/navigate_307494/Indoor_Outdoor_Plenum_Adventum_LTP_.html http://www.berktek.com