TSU Specifications and Ordering Information Load Cells & Readouts Specifications Gage Resistance 350 Ω Excitation Voltage 10 VDC maximum Output Signal 21 mVDC maximum per load cell at full load rating Operating Temperature -30˚ to 95˚ C Temperature Effect on Zero .02% of rating per ˚C Combined Non-linearity and Hysteresis .5% of full scale maximum Repeatability .2% of full scale maximum Overload Stops Internal at 105% to 150% of full load rating Deflection at Full Load 23 mm (0.009 inch) Weight TSU-1, 4 1/4 lb; TSU-2, 10 1/2 lb; TSU-3, 36 lb Mating Cable Assembly Use SCE Cable series Mating Connector Only 12B193-6 (pin A + power; pin B + signal; pin C - signal; pin D - power) Ordering Information Model TSU Load Cells are used in pairs-one on each side of the web. When ordering you must specify one left hand unit and one right hand unit for each sensing roll. Order by model number as shown in the following example. TSU Model Number 74 Load Cells & Readouts Size Example: A requirement for a 1,000 lb capacity load cell of size 2, as shown in the dimension sheet would be specified as TSU2-1000-L for the left side of the sensing roll and as TSU2-1000-R for the right side of the sensing roll. 2 1000 L Force Rating Configuration (R) RIGHT (L) LEFT