DLCA Specifications and Applications Supply Power 24 VDC, +/- 10%, 0.14 ADC maximum Inputs Display 4-digit LED Enclosure IP20 5 or 7.5 VDC, 100mADC maximum Mounting DIN 35 Rail Load Cell Sensitivity 1.5 to 100 mV/V single sensor or pair Certifications Digital Input (re-zero) 24 VDC maximum 5 VDC or 24 VDC selectable threshold CE TUV Mark (UL61010-1) CAN/CSA-C22.2# 61010-1 CB to IEC 61010-1 RoHS Temperature Range Operating: 0 to 50 degrees C (32 to 122 degrees F) Outputs Analog Outputs 0 to 10 VDC, 5mA, 2 kohm minimum load 4 to 20 mADC, 450 ohm maximum load Reference Meter Output 0 to 1 mADC, 1 kohm maximum load or 0 to 10 VDC, open circuit Alarm Output 30 VDC maximum, 0.4 ADC maximum Gain 32:1 Load Cells & Readouts Load Cell Excitation Storage: -20 to 80 degrees C (-4 to 176 degrees F) Climate Class 3K3 (EN60721) Options Power Converter 85 to 264 VAC to 24 VDC Din-Rail Mount Part Number 93157-024 Load Cells & Readouts 79