TR-5 Dimensions, Specifications and Applications Load Cells & Readouts Specifications TR-5 Supply Power 115/230 VAC ± 10%, 50/60 Hz, switch selectable, 6VA Tension Input 0 to 21 mV (one or two 350 Ω full bridges), 0 to 500 mV (one 120 Ω full bridge), selectable INTERNAL ADJUSTMENTS Gain Calibrates meter (full scale) with load cell loading from 1/8 to full rating Zero (Tare) Up to 50% of combined load cell rating TR-5 Output 0 to 10 VDC or 4 to 20 mADC Accuracy Maximum null drift .005% of load cell rating per ˚C. Maximum gain drift .02% of reading per ˚C TR-5 Meter 4 inch x 6 inch, 1 mADC scaled 0 to 100% Temp. Range 0 to 40˚ C operating -30˚ to 65˚ C storage 5 or 10 VDC Weight 5.5 kg (12 lb) Enclosure IP20 Tension Load Cell Excitation Dimensions shown in inches (mm) Load Cells & Readouts 83