Typical Details | FAS Track 1000 HW-D-0514 STANDARD WALL, PERPENDICULAR TO FLUTED DECK HW-D-0550 2 HR. GYPSUM WALLBOARD CEILING* FLUTED METAL DECK WITH CONCRETE SPRAY FIREPROOFING Z-CLIP 3/4" JOINT PROTECTION CEMCO FAS TRACK 1000 #8 x 1/2" FRAMING SCREW DRYWALL SCREW 1" LOWER THAN TRACK LEG METAL STUD BY DESIGN 5/8" TYPE "X" DRYWALL CONFIGURATION "B" 5 NOTE: DOUBLE LAYER FOR 1 HOUR FIREFIRE RATING 8" TYPE *NOTE: SINGLE LAYER OFOF5/8" TYPE "X" "X"DRYWALL DRYWALL FOR 1 HOUR RATING, 2 LAYERS FOR 2 HOUR HW-D-0551 1 HR. CENTERED DIRECTLY UNDER BEAM *NOTE: SINGLE LAYER OF 5/8" TYPE "X" DRYWALL FOR 1 HOUR FIRE RATING, 2 LAYERS FOR 2 HOUR HW-D-0553 2 HR. CHASE WALL, PERPENDICULAR TO FLUTED DECK FLUTED METAL DECK WITH CONCRETE FILL FIRE PROOFING OR MINERAL WOOL STEEL BEAM TYPICAL STEEL FASTENERS BY DESIGN STRUCTURAL STEEL FIREPROOFING (THICKNESS BY OTHERS) 1/2" x 20 GA. Z-BAR OR 16 GA. CRC @ BY DESIGN 3/4" JOINT PROTECTION CEMCO FAS TRACK 1000 #8 x 1/2" FRAMING SCREW DRYWALL SCREW 1" LOWER THAN TRACK LEG METAL STUD BY DESIGN 5/8" TYPE "X" DRYWALL CONFIGURATION "B" *NOTE: SINGLE LAYER OF 5/8" TYPE "X" DRYWALL FOR 1 HOUR FIRE RATING, 2 LAYERS FOR 2 HOUR HW-D-0554 2 HR. CHASE WALL, CONCRETE SLAB *NOTE: SINGLE LAYER OF 5/8" TYPE "X" DRYWALL FOR 1 HOUR FIRE RATING, 2 LAYERS FOR 2 HOUR *NOTE: SINGLE LAYER OF 5/8" TYPE "X" DRYWALL FOR 1 HOUR FIRE RATING, 2 LAYERS FOR 2 HOUR HW-D-0573 1 & 2 HR. FLUTED DECK BEAM PENETRATION *NOTE: SINGLE LAYER OF 5/8" TYPE "X" DRYWALL FOR 1 HOUR FIRE RATING, 2 LAYERS FOR 2 HOUR Head of Wall Systems | www.cemcosteel.com | 800.775.2362 25http://www.cemcosteel.com